PLASMADETEK 2

Plasma emission detector for gas chromatograph

This microprocessor based plasma emission detector system gives all the tools to the GC integrator, manufacturer and user to integrate a plug and play detection system. With its customable configuration capability, a detector has never been so intelligent.

THE PLASMADETEK 2 SPECIFICATION

CARRIER GAS
  • Argon and Helium
POWER
  • 80 to 240 VAC, 50-60 Hz
GAS CONNECTIONS
  • 1/16'' (can be customized)
OPERATION OUTLET PRESSURE
  • Atmospheric or Vacuum
OPERATING TEMPERATURE
  • 10°C to 50°C (in stable environment)
FILTER
  • 10u SS particle filter on the gas inlet
DETECTOR SIGNAL OUTPUT CONNECTION
  • BNC Coaxial type (can be customized)
POWER CONSUMPTION
  • Max 10 Watts



Picture Gallery


 
 

PLASMADETEK 2 Application Notes

LD16-05 - Refinery gas analyses with MultiDetek2 compact gas chromatograph and PlasmaDetek2 gas detector

AN_LD16-05 (916 ko)

LD16-04 - Sulfur Hexafluoride (SF6) purity analysis using the MultiDetek 2 and PlasmaDetek 2

AN-LD16-04 (496 ko)

LD16-03 - Measurement of part per billion H2-NMHC-CH4-N2-CO2-CO for semiconductor gases

Application note_LD16-03 (1,66 Mo)

LD16-02 - Analysis of hydrocarbons, CO2, N2O in Oxygen with the MultiDetek2 compact GC system using Nitrogen as carrier gas and the PlasmaDetek-E detection technology

Application note_LD16-02 (665 Ko)

LD16-01 - Air analysis using the MultiDetek2 and PlasmaDetek2

Application note_LD16-01 (955 Ko)

LD15-09 - Measurement of THT in natural gas using MultiDetek2 and PlasmaDetek2

Application note_LD15-09 (1,38 mo)

LD15-08 - Measurement of impurities in UHP helium using MultiDetek2 and PlasmaDetek2

Application Note LD15-08 (0,8 Mo)

LD14-01 - Light hydrocarbons measurement with the *PlasmaDetek-E system with nitrogen carrier gas and the MultiDetek-2.

Application Note LD14-01 847 Ko

LD13-01 - Analysis of UHP Hydrogen production using Plasmadetek-2 & micro GC Multidetek-2

Application Note LD13-01.pdf (1.1 Mo)

LD12-8 Analysis of Sulfurs with the PlasmaDetek

Application Note LD12-8 (1,1 Mo)

LD12-7 Analysis of Neon-Hydrogen-Argon-Krypton-Nitrogen with the PlasmaDetek & the HSR-Etek column

Application Note LD12-7 (819 Ko)

LD12-4 Analysis of nitrogen in hydrogen and oxygen bulk with the PlasmaDetek

Application Note LD12-4 (1,4 Mo)

LD12-3 Analysis of argon in pure oxygen with the PlasmaDetek and ArgoTek

Application Note LD12-3 (565 Ko)

LD12-2 Analysis of permanent gases and light hydrocarbons with the PlasmaDetek

Application Note LD12-2 (328 Ko)

LD12-1 Greenhouse analysis with the PlasmaDetek

Application Note LD12-1 (807 Ko)